Most transom window sizes follow one simple pattern: the transom is 12 to 18 inches tall and exactly as wide as the door or window below it. A transom over a standard 36-inch entry door is 36 inches wide and usually 12, 14 or 18 inches tall. Height is the only real choice, and your ceiling height makes most of that decision for you, as the ceiling test below shows.
Transom window size chart by placement
A transom is a separate glazed unit set above a door or window, divided from it by a horizontal frame member called the transom bar. Because the width is inherited from the unit below, manufacturers size transoms by the assembly they sit on. These are the standard ranges across major catalogs and installer guides.
| Placement | Standard width | Minimum height | Ideal height | Notes |
|---|---|---|---|---|
| Above a single entry door | 32 to 38 in | 12 in | 12 to 18 in | Matches the door unit; 36 in is the most common door width |
| Above double or French doors | 60 to 72 in | 12 in | 14 to 24 in | One wide unit spanning both slabs |
| Above an interior door | 24 to 36 in | 10 in of glass | 10 to 14 in of glass | Site-built fixed pane; borrows light between rooms |
| Above a window | Matches window below | 12 in | 12 to 24 in | Twin and triple units run 35 1/2 to 143 1/2 in wide |
| Above a patio door | 60 to 96 in | 12 in | 24 in | Pella’s standard patio transom height is 24 in |
Two patterns matter in that chart. First, the width is never a free choice: order a transom wider or narrower than the unit below and the frame lines will not line up. Second, heights cluster on a few stock steps. Andersen’s A-Series fixed transoms, for example, come in unit heights of 12, 16, 18, 20, 22 and 24 inches, so a “custom” 15-inch transom usually means paying custom prices for a stock look.
How tall should a transom window be?
For an 80-inch door, a transom height of 12 to 18 inches keeps the proportions right: that is 15 to 22.5 percent of the door height (80 × 0.15 = 12; 80 × 0.225 = 18). Go much past 24 inches (30 percent of the door) and the glass starts to read as a clerestory band rather than a transom, which is a fine look, just a different one.
Interior transoms follow a slightly different target because they are usually site-built rather than ordered from a catalog. Builders aim for 10 to 12 inches of visible glass above an interior door: enough to pass useful daylight into a hall or bathroom with the door closed, without making the door below look cut short. A transom also needs roughly 10 inches of clear wall between the top of the door casing and the ceiling before it is worth attempting at all.
The ceiling test: how much transom your ceiling allows
The fastest way to size a transom is to work down from the ceiling, not up from the door. An 80-inch door leaves a fixed band of wall above it, and the transom, its frame and the trim all have to share that band.
| Ceiling height | Wall band above an 80 in door | Biggest practical transom | Verdict |
|---|---|---|---|
| 8 ft (96 in) | 16 in | 12 in | Minimum: only the shortest stock transom fits, with slim trim |
| 9 ft (108 in) | 28 in | 24 in | Ideal: the full 12 to 18 in range fits comfortably |
| 10 ft (120 in) | 40 in | 24 in | Ideal: taller is possible, but 18 to 24 in keeps the proportion |
The arithmetic is unforgiving at 8 feet. The band is 96 − 80 = 16 inches. The door head frame and transom bar take about 2 inches of it, and you want about 2 inches of clearance below the ceiling for trim and framing tolerance: 16 − 2 − 2 = 12 inches left, which is exactly the shortest stock transom. This is why so many 8-foot-ceiling homes have no transoms, and why an 8-foot (96-inch) door in the same house leaves no room for one at all: 96 − 96 = 0.
At 9 feet the same math gives 108 − 80 = 28 inches of band, and after the same 4 inches of allowances a 24-inch transom fits exactly, with nothing left over. The combined unit also explains the proportions you see in older homes: an 80-inch door plus a 12 to 18 inch transom plus frame lands at 96 to 100 inches total, which is why transoms belong to 9 and 10 foot ceiling houses.

Fixed vs operable transom sizes
Most transoms are fixed: a sealed pane that only passes light. Operable transoms open for ventilation, usually as an awning (hinged at the top) or a hopper (hinged at the bottom), and they need more height because the sash frame and hardware take up more of the unit.
| Type | Shortest stock unit height | Typical range | Notes |
|---|---|---|---|
| Fixed (picture) transom | 12 in | 12 to 24 in | Most glass per inch of height; the default choice |
| Operable (awning or hopper) transom | 16 in | 16 to 24 in | Andersen’s venting line starts at 16 in; fixed starts at 12 in |
| Site-built interior transom | 10 in of glass | 10 to 14 in of glass | Fixed pane in a trim frame, sized to the opening |
Height also buys less glass than people expect. In Andersen’s A-Series frame, a 12-inch fixed transom shows only 8 5/8 inches of unobstructed glass: the frame and sash eat 3 3/8 inches (12 − 8 5/8 = 3 3/8). An 18-inch unit shows 14 5/8 inches. If daylight is the goal, that glass number, not the unit number, is the one to compare, and it is a strong argument for choosing 18 inches over 12 whenever the ceiling allows it.
Transom sizes above windows and patio doors
Above a window, the transom matches the window unit’s width and typically runs 12 to 24 inches tall. Wide window walls use mulled twin and triple transoms: Andersen’s 100 Series lists twin transoms from 2 feet 11 1/2 inches to 7 feet 11 1/2 inches wide and triples from 4 feet 5 1/2 inches to 11 feet 11 1/2 inches, all in the same 12 to 24 inch height band.
Patio doors sit at the tall end. Pella’s 350 Series sliding patio doors pair 5, 6, 7 1/2 and 8 foot door widths with a 24-inch transom as the standard offering, because a patio wall usually has the ceiling height to carry it. Arched and half-round (fanlight) transoms are the exception to every chart in this article: they are made to order for the opening, and there are no standard sizes for them.
How to measure for a transom window
- Measure the unit below. Record the full frame-to-frame width of the door or window unit, not just the slab. A 36-inch door in its frame is the width your transom must match. If you are planning a new doorway at the same time, check standard doorway dimensions first so the pair is sized together.
- Measure the band above the door. From the top of the door frame to the ceiling (or to the header on an exterior wall), record the clear height at both ends; old houses are rarely level.
- Subtract the allowances. Take off about 2 inches for the transom bar and head frame and 2 inches of trim and framing clearance at the top. What remains is your maximum unit height.
- Pick the stock height at or below that number. On a 9-foot ceiling with an 80-inch door: 28 − 4 = 24, so any stock height up to 24 inches works, and 14 to 18 inches is the sweet spot.
- Convert to a rough opening. The framed rough opening is typically the unit size plus 1/2 inch in width and height. A unit ordered at 36 × 14 inches needs a rough opening of about 36 1/2 × 14 1/2 inches; confirm against the manufacturer’s sizing table before framing.
For interior doors, the same five steps apply, with one addition: check what the transom will light. A transom over a bedroom or bathroom door spills light both ways at night, which is why frosted glass is common there, while a transom over a home office door on a hall is usually clear. The hallway dimensions guide covers the hall widths and door placements these interior transoms usually serve.
Common sizing mistakes
- Ordering by glass size instead of unit size. A “12-inch transom” from a catalog is a 12-inch unit that shows about 8 5/8 inches of glass. Measure and order in unit dimensions.
- Ignoring the ceiling. A 24-inch transom over an 80-inch door needs a 9-foot ceiling. On an 8-foot ceiling it physically does not fit once frame and trim are counted.
- Mismatching the width. A transom narrower than the door unit below leaves the frame lines offset, which reads as a mistake from across the room.
- Assuming a transom can vent a bathroom alone. Operable transoms start at 16 inches and move little air at ceiling height; treat them as a supplement, not the ventilation plan.
- Forgetting the divided-lite pattern. If the door below has a grille pattern, the transom should repeat it; a plain transom over a divided-lite door looks like a replacement part.
How Much Does a Transom Window Cost?
A replacement transom in an existing opening costs $334 to $711 installed, with a national average of $459. Materials run $249 to $531 and labor $70 to $150. A new opening costs far more, $825 to $2,500 installed, averaging $1,730, because cutting the wall needs a header and framing, and a load-bearing wall adds $200 to $500 on top. Fixed rectangular units are the cheapest at $120 to $300; arched and fanlight styles run $350 to $710 or more.
| Style | Installed cost |
|---|---|
| Fixed rectangular | $120 to $300 |
| Arched or fanlight | $350 to $710 or more |
| Replacement in an existing opening | $334 to $711 (average $459) |
| New opening | $825 to $2,500 (average $1,730) |
Frequently asked questions
What is the standard size of a transom window?
There is no single standard, but the common residential size is 12 to 18 inches tall and as wide as the door or window below it. Over a standard 36-inch entry door, that means a 36 × 12, 36 × 14 or 36 × 18 inch unit covers the large majority of installations.
What is the minimum height for a transom window?
The shortest stock fixed transom is a 12-inch unit (Andersen’s A-Series starts there), and the shortest operable transom is 16 inches because the moving sash needs the extra frame. Site-built interior transoms can go slightly smaller, to about 10 inches of visible glass, below which the pane passes little useful light.
How wide should a transom window be?
Exactly as wide as the unit below it, frame to frame. That is 32 to 38 inches over a single entry door, 60 to 72 inches over double doors, and the full width of the window or patio door for above-window and patio placements. Width is a match, not a choice.
Can a transom window count as an egress window?
No. Egress windows must open to a set clear area with the sill no more than 44 inches above the floor, and a transom fails on height, size and usually operation all at once. Bedrooms still need a full egress window that meets the egress window size requirements; a transom is daylight only.
Does a transom window above a door need tempered glass?
Usually not under the door rule. IRC Section R308.4.2 treats glazing near a door as a hazardous location when its bottom edge is less than 60 inches above the floor and within 24 inches of the door edge. A transom’s bottom edge sits at about 82 to 84 inches, above that threshold. Other rules can still apply to very large panes, so confirm with your local code office before ordering.
How much does a transom add to the total door height?
An 80-inch door plus a 12 to 18 inch transom plus the frame between them totals 96 to 100 inches. That combined height is the number to check against your ceiling and header before you commit to a pre-hung door-and-transom unit.
The short version
Pick the width by matching the unit below, then let the ceiling pick the height: 12 inches is the practical floor, 18 inches is the sweet spot on a 9-foot ceiling, and 24 inches is the ceiling of the standard range, reserved for patio doors and tall rooms. Measure the band above the door, subtract 4 inches of frame and trim, and order the largest stock size that fits what is left.
Sources
- Andersen A-Series transom size chart: used for stock fixed and venting unit heights and unobstructed glass sizes.
- Andersen 100 Series product guide, twin and triple transom table: used for twin and triple transom width ranges.
- Pella 350 Series size tables: used for patio door transom widths and the 24-inch standard height.
- Rooster Windows and Doors, Transom Window Dimensions: used for placement-by-placement size ranges and rough opening tolerance.
- RoomSketch3D, Window Types in Floor Plans: used for the standard 12 to 18 inch height range and width-matching rule.
- Holland & Sons, Transom Windows Above Interior Doors: used for interior transom glass targets and the 10-inch clearance rule.
- Thompson Creek, What Is a Door Transom?: used for combined door-plus-transom opening heights.
- OKNOPLAST, Transom Windows guide: used for the IRC R308.4.2 safety glazing threshold and frame arithmetic.
- Rustica, Transom Windows: Types, Placement and Planning: used for standard rough opening widths and heights and the arched transom note.
- Modernize, Transom Windows: used for the installed replacement cost range and the $459 national average.
- This Old House, Transom Windows: used for the new-opening cost range and its $1,730 average.