Egress window size requirements come from IRC Section R310, and they are four numbers that all apply at once. The window must open to a net clear opening of at least 5.7 square feet, at least 24 inches high and 20 inches wide, with the sill no more than 44 inches above the floor. A grade-floor opening needs 5.0 square feet. Meet any three and miss the fourth, and the window fails.
Egress window requirements at a glance
The table below is the full rule set for a bedroom egress window under the 2021 IRC. The 2024 edition renumbered the section to R319 and kept the same four numbers. Your local code office enforces its own adopted edition, so treat these as the national model-code figures and confirm local amendments before you order a window.
| Requirement | IRC minimum | Notes |
|---|---|---|
| Net clear opening area | 5.7 sq ft (820.8 sq in) minimum | Measured on the open window, not the frame or label size |
| Net clear opening area, grade-floor opening | 5.0 sq ft (720 sq in) minimum | Sill within 44 in of the ground outside |
| Net clear opening height | 24 in minimum | Applies on its own; meeting it does not guarantee the area |
| Net clear opening width | 20 in minimum | Applies on its own; a wide-enough window can still fail on area |
| Sill height | 44 in maximum | Finished floor to the bottom of the clear opening |
| Window well area (below-grade windows) | 9 sq ft minimum, 36 in minimum width and projection | Ladder or steps required if the well is deeper than 44 in |

Why a 20 by 24 inch window fails
A window built exactly to the height and width minimums still fails, because the area rule is separate. Multiply it out: 20 inches times 24 inches is 480 square inches, and 480 divided by 144 is 3.33 square feet. That is 340.8 square inches short of the 820.8 square inches the code requires. The two minimums describe the smallest legal hole in each direction, not a window size that passes.
To reach 5.7 square feet at the minimum width of 20 inches, the opening has to be 41.04 inches high (820.8 divided by 20). At the minimum height of 24 inches, it has to be 34.2 inches wide (820.8 divided by 24). One dimension always has to overshoot its minimum by a wide margin, and the chart below shows the trade-off at every clear width.
| Clear width | Clear height needed for 5.7 sq ft | Clear height needed for 5.0 sq ft (grade floor) |
|---|---|---|
| 20 in | 41.1 in | 36.0 in |
| 22 in | 37.4 in | 32.8 in |
| 24 in | 34.2 in | 30.0 in |
| 26 in | 31.6 in | 27.7 in |
| 28 in | 29.4 in | 25.8 in |
| 30 in | 27.4 in | 24.0 in |
| 32 in | 25.7 in | 24.0 in (height minimum governs) |
| 34.2 in | 24.0 in (height minimum governs) | 24.0 in (height minimum governs) |
Heights are rounded up to the nearest tenth of an inch. Once the clear width reaches 34.2 inches, the 24 inch height minimum takes over, and any opening at least that tall also passes on area.
Net clear opening is not the window size
Net clear opening is the open hole a person can actually climb through, measured with the window opened the normal way, from inside the room, with no keys, tools, or special knowledge. It is not the frame size, not the rough opening, and not the number printed on the window label. Frames, sashes, stops, and hardware all subtract from it.
How much you lose depends on the window type. A double-hung opens only its lower half, so roughly half the unit height counts. A sliding window opens about half its width; Andersen’s published figure for its 100 Series gliding windows puts the clear width at half the unit width minus 3.71 inches. A casement swings nearly the whole sash clear, which is why casements reach the area target at smaller unit sizes than double-hungs.
Window sizes that pass, and two that fail
The clearest way to see the gap between unit size and clear opening is a manufacturer’s own egress data. Andersen publishes net clear openings for its 400 Series windows, and five common units show every verdict the rules can produce.
| Window (unit size) | Type | Net clear opening | Clear area | Verdict |
|---|---|---|---|---|
| Andersen TW2846, 33 5/8 x 56 7/8 in | Double-hung | 29 7/8 x 24 1/4 in | 5.03 sq ft | Fails the 5.7 sq ft rule; passes only as a grade-floor opening |
| Andersen TW2852, 33 5/8 x 60 7/8 in | Double-hung | 29 7/8 x 27 3/4 in | 5.76 sq ft | Passes |
| Andersen TW3046, 37 5/8 x 56 7/8 in | Double-hung | 33 7/8 x 24 1/4 in | 5.70 sq ft | Passes, with no margin |
| Andersen C15, 24 1/8 x 59 7/8 in | Casement | 18 5/16 x 55 in | 6.99 sq ft | Fails: clear width is under the 20 in minimum |
| Andersen CX135, 31 1/2 x 40 13/16 in | Casement | 25 11/16 x 35 15/16 in | 6.41 sq ft | Passes |
Read the pattern, not just the rows. Two of the double-hungs share the same unit height and differ only in width, and the narrower one fails: on a double-hung, width is what buys area. The tall casement fails the other way, with 6.99 square feet of area and a clear width under 20 inches. Area, height, and width are checked independently, so a window has to win all three at once. The figures are Andersen’s published clear openings for these units; other brands differ, so check the maker’s egress table before ordering.
The 44-inch sill rule
The bottom of the clear opening can sit no more than 44 inches above the finished floor. The measurement runs from the floor to the bottom of the open hole, not to the top of the sill board or the window frame, and on a double-hung the raised lower sash is what sets that bottom edge.
The sill rule is about reach: a child or a smaller adult has to be able to climb up and out unaided. Furniture placed under the window does not change the measurement, and neither does a platform you plan to add later. On a new build or an addition, the sill height is set at framing, long before the window unit is picked, so it has to be planned with the window, not after it.
When 5.0 square feet is enough: grade-floor openings
A grade-floor opening is one where the bottom of the clear opening sits within 44 inches above or below the finished ground level outside. Those openings get the reduced area minimum of 5.0 square feet (720 square inches), because a person climbing out steps down to grade instead of dropping into a well or onto a lower roof.
The height and width minimums do not change: still 24 inches and 20 inches. At the 20 inch minimum width, a grade-floor opening needs 36 inches of clear height (720 divided by 20). At 24 inches high, it needs 30 inches of width. A first-floor bedroom window with its sill within 44 inches of the ground outside is the common case, and it is the one case where a window at 5.03 square feet, like the narrower double-hung above, still complies.
Basement egress windows and window wells
A basement window whose sill sits below the ground outside needs a window well, and the well is part of the requirement: at least 9 square feet of horizontal area, with a minimum width and projection of 36 inches each. The well has to let the window open fully and give a person standing in it room to climb out.
If the well is deeper than 44 inches, it needs a permanently attached ladder or steps. Our guide to basement bedroom requirements works through the full basement case, including the ceiling height and room size rules that apply alongside the window.
How to measure a window for egress
You need a tape measure and five minutes. Work through the window you have, in this order:
- Open the window fully, the normal way, from inside the room. Do not remove sashes or stops.
- Measure the clear width at the narrowest point, between the frame, stops, sash, and any hardware sitting in the opening.
- Measure the clear height the same way, from the bottom of the opening to the top.
- Multiply the width by the height in inches, then divide by 144 to get square feet.
- Measure the sill height from the finished floor to the bottom of the clear opening.
- Compare all four results against the minimums: 5.7 square feet (5.0 at grade floor), 24 inches high, 20 inches wide, sill at or under 44 inches.
If one number misses, the window misses. The most common surprise is a double-hung that looks generous on the wall and delivers under 5 square feet of clear opening once the sash is raised.
Which rooms need an egress window
Every sleeping room needs at least one emergency escape and rescue opening, and so does any basement with habitable space and any habitable attic. The opening has to lead directly outside, to a public way or to a yard or court that reaches one. An exterior door can serve as the opening; a window is simply the usual way bedrooms meet the rule.
Egress is one of the tests that decide whether a room counts as a bedroom at all. Our guide to the minimum bedroom size covers the floor-area side of that test (70 square feet, and 7 feet in any direction), and what qualifies as a bedroom pulls the full list together, including the closet question. A room can pass on floor area and still fail as a legal bedroom on the window alone.
Egress window FAQs
What is the minimum egress window size for a bedroom?
There is no single minimum window size, because the code sets an opening, not a unit. The opening has to reach 5.7 square feet of net clear space, at least 24 inches high and 20 inches wide, with the sill at or under 44 inches. In unit terms, most double-hungs need to be roughly 3 feet wide and 5 feet tall to get there, and the Andersen table above shows a 33 5/8 by 56 7/8 inch unit failing at 5.03 square feet.
Can a sliding window count as an egress window?
Yes, if its clear opening passes all four checks. A slider only opens about half its width, so it needs a wide unit. Check the area math on the open half rather than the full unit, and confirm the clear width still reaches 20 inches after the sliding sash, frame, and stops take their share.
Does an egress window have to open a certain way?
It has to open from inside, by normal operation, without keys, tools, or special knowledge, and it has to stay openable. Security bars or grilles are only permitted if they release from inside the same way. A fixed picture window never counts, however large it is.
What if my existing bedroom window is too small?
For a new window, or a renovation that triggers a permit, the replacement has to meet the current numbers. The usual fixes are a wider unit, a taller unit, or a casement in the same rough opening, since a casement clears more area per unit size. Rules for untouched existing homes vary by jurisdiction, so check with the local code office before assuming a small window is grandfathered.
Do all the windows in a bedroom need to meet egress sizes?
No. One compliant emergency escape and rescue opening per sleeping room is the requirement. The other windows in the room can be any size, fixed or operable.
Sources
- Linn County Building Division, Egress Windows (IRC Section R310 guidelines): used for the four R310 minimums and the width and height combination chart.
- IRC Section R310, Emergency Escape and Rescue Openings (full code text): used for the operational rules and the window well requirements.
- SizeMarker: Andersen 400 Series double-hung clear opening data: used for the double-hung unit sizes and clear openings in the size table.
- SizeMarker: Andersen 400 Series casement clear opening data: used for the casement unit sizes and clear openings in the size table.


2 Comments
Pingback: Minimum Bedroom Size: 70 Sq Ft, 7 Ft Wide (Code Minimum)
Pingback: Basement Bedroom Requirements: The 5.7 Sq Ft Egress Rule