A standard doorway in a home is 36 inches wide at the front door and 30 to 32 inches wide inside, all 80 inches tall. But the number that decides whether a person, a wheelchair, or a sofa passes is the clear opening, not the slab size. A 36 inch door gives about 34 inches clear, which passes the 32 inch code minimum with room to spare, while a 32 inch door gives only about 30 inches clear, which fails.
What are doorway dimensions?
Definition: doorway dimensions are the four numbers that describe one opening: the slab size (the door panel itself), the clear opening (the usable width and height a person or a piece of furniture actually passes through), the rough opening (the framed hole in the wall that the door unit sits in), and the jamb depth (the frame depth that must match the wall thickness). A doorway quoted only as 36 inches has not yet told you any of the other three, and the other three are where orders go wrong.
The confusion is understandable, because door sellers, builders, and code books each lead with a different number. A seller lists the slab. A builder frames the rough opening. A code book enforces the clear opening. This guide keeps all three visible at every step, so a reader can check a seller listing against a framed hole against a code minimum without converting in their head.
Measure finished surfaces, not rough framing, for the clear opening. Trim, stops, thresholds, and flooring all take fractions off the numbers on a floor plan, and a doorway that measures 36 inches stud to stud can measure 34 inches clear once the frame, the stop, and the open door are counted. Measure every doorway in the house separately, because front, bedroom, bathroom, and closet doors are rarely the same size, and the narrowest one on a route decides the route.
Standard doorway dimensions at a glance
Every size below is a finished size for a typical American home. Slab means the door panel. Clear means the usable opening with the door open at 90 degrees, approximated as slab minus about 2 inches (explained in the clear opening section). Rough opening means the framed hole for a prehung unit: slab width plus 2 inches, slab height plus 2.5 inches.
| Doorway | Slab size | Clear opening, about | Rough opening | Best for |
|---|---|---|---|---|
| Front entry, single | 36 x 80 in | 34 in wide | 38 x 82.5 in | Main entrance, egress, furniture deliveries |
| Bedroom | 30 to 32 x 80 in | 28 to 30 in wide | 32 to 34 x 82.5 in | Daily use; 32 in is the common pick |
| Bathroom | 28 to 30 x 80 in | 26 to 28 in wide | 30 to 32 x 82.5 in | Small rooms; 28 in is the common pick |
| Closet, bifold opening | 24 to 36 in wide x 80 in | Less than the opening | Varies by track | Reach-in storage; access is narrower than the opening |
| Utility, laundry, pantry | 24 to 30 x 80 in | 22 to 28 in wide | 26 to 32 x 82.5 in | Narrow end of the interior range |
| Double entry, total | 60, 64, or 72 in wide x 80 in | One leaf must give 32 in clear where required | Combined slabs plus 2 in | Wide entries; check the active leaf, not the total |
| Accessible doorway | 36 in slab x 80 in | About 34 in clear | 38 x 82.5 in | Wheelchair passage with margin |

Published guides land in the same bands with different labels. The standard exterior front door size is 36 inches wide by 80 inches tall in the Doors.com standard door size guide, with standard interior doors typically 30 to 32 inches wide and 80 inches tall, and widths ranging from 24 to 36 inches depending on room type. Statement Design Concepts puts the front door at 36 inches, interior doors between 28 and 32 inches, and bedroom doors most commonly at 32 inches, with bathroom doors most commonly at 28 inches. The Window Sunshine door size guide agrees on the 36 by 80 inch exterior baseline and the 30 to 32 inch interior baseline, with 36 inches for accessibility. The spread is real, because a doorway width follows its room, its traffic, and its code job. The sections below derive each row from the clear opening outward.
The 32-36-80 rule
Three numbers size almost every home doorway. Learn them in order, and every other decision becomes a check against one of them.
32 inches is the clear minimum. Both the residential egress rule and the accessible route rule require a clear opening of at least 32 inches, measured with the door open at 90 degrees between the face of the door and the stop. The International Residential Code requires the egress door of a dwelling to provide that 32 inch clear width and a 78 inch clear height, and the ADA Standards for Accessible Design set the same 32 inch clear width for doors on an accessible route. A doorway narrower than 32 inches clear fails both tests, whatever its slab size says.
36 inches is the slab that delivers it. A 36 inch slab, once the open door and the stop are counted, leaves about 34 inches clear, which passes the 32 inch minimum with 2 inches to spare. That is why 36 by 80 inches became the standard front door and the standard accessible door: it is the smallest common slab that clears the minimum with margin instead of exactly. A 34 inch slab lands on about 32 inches clear, which passes exactly and leaves no margin for a thick stop, a closer, or a slightly out-of-square frame. A 32 inch slab lands on about 30 inches clear, which fails, and this is the single most common doorway misunderstanding in home buying: people read 32 on the slab and assume 32 of passage.
80 inches is the height. The standard door height in American homes is 80 inches, which is 6 feet 8 inches, for interior and exterior doors alike. The egress clear height minimum is 78 inches measured from the top of the threshold to the bottom of the stop, so an 80 inch door clears it with 2 inches to spare, the same margin logic as the width. Taller options exist at 84 inches (7 feet) for 9 foot ceilings and 96 inches (8 feet) for 10 foot ceilings and grand entries, and each one raises its rough opening by the same amount. Height is the least argued doorway number, because 80 inches fits the standard wall, the standard frame, and the standard person, and only ceiling height pushes it up.
Slab, clear, and rough opening: three different widths
A door slab is the panel that swings. A clear opening is the passage that remains when that panel is open at 90 degrees. A rough opening is the framed hole the whole unit drops into. Confusing any two of them is how a door arrives that cannot fit its frame, or a frame gets built that cannot pass a wheelchair.
Slab width is the panel width as sold: 24, 28, 30, 32, 34, or 36 inches in 2 inch steps for most residential doors. Thickness matters here too: interior slabs are 1-3/8 inches thick, exterior slabs are 1-3/4 inches thick, because an exterior door must resist weather and forced entry while an interior door only needs to close a room.
Clear width is measured with a swinging door open at 90 degrees, from the face of the door to the opposite stop. That is the ADA measurement method and the IRC egress measurement method, and it is the only width that answers the question "will this pass through?" This guide approximates clear width as slab width minus about 2 inches: the open door itself, at 1-3/8 inches thick for an interior slab, plus the stop and hinge-side framing it stands against, consume roughly that much. The figure is an estimating rule, not a factory guarantee, and it varies with the frame and the hardware, which is why the measuring section tells you to tape the actual door rather than trust the subtraction alone.
| Slab width | Clear width, about | Margin against the 32 in minimum | Verdict |
|---|---|---|---|
| 28 in | 26 in | 6 in short | Fails |
| 30 in | 28 in | 4 in short | Fails |
| 32 in | 30 in | 2 in short | Fails |
| 34 in | 32 in | Exactly at the minimum | Passes, no margin |
| 36 in | 34 in | 2 in to spare | Passes with margin |
Read the table as a buying rule. If a doorway must pass a wheelchair, an egress inspection, or a wide piece of furniture, buy the 36 inch slab, not the 32 inch slab. A 32 inch slab is a fine bedroom door for daily walking, and it is a failing accessible door, and both statements are true at the same time, because the jobs are different.
Rough opening width is the stud to stud width of the framed hole, and it runs about 2 inches wider than the slab, to leave room for the jamb, shims, and adjustment. Rough opening height runs about 2.5 inches taller than the slab, to leave room for the head jamb and floor clearance. The formulas, confirmed across the rough opening guides in the Sources section, are:
Rough opening width = slab width + 2 inches
Rough opening height = slab height + 2.5 inches
| Slab size | Rough opening | Check |
|---|---|---|
| 24 x 80 in | 26 x 82.5 in | 24 + 2 = 26; 80 + 2.5 = 82.5 |
| 28 x 80 in | 30 x 82.5 in | 28 + 2 = 30; 80 + 2.5 = 82.5 |
| 30 x 80 in | 32 x 82.5 in | 30 + 2 = 32; 80 + 2.5 = 82.5 |
| 32 x 80 in | 34 x 82.5 in | 32 + 2 = 34; 80 + 2.5 = 82.5 |
| 34 x 80 in | 36 x 82.5 in | 34 + 2 = 36; 80 + 2.5 = 82.5 |
| 36 x 80 in | 38 x 82.5 in | 36 + 2 = 38; 80 + 2.5 = 82.5 |
| 36 x 84 in | 38 x 86.5 in | 36 + 2 = 38; 84 + 2.5 = 86.5 |
One caution belongs with this table. Exterior prehung units sometimes need a slightly wider or shorter rough opening than the interior formula, because of thicker jambs, weatherstripping, and the sill or threshold, and one rough opening guide gives 38.5 by 82.25 inches for a 36 inch exterior door against the interior formula's 38 by 82.5 inches. Always check the manufacturer's own rough opening spec for an exterior unit before framing, and treat the formula as the planning number, not the final cut list.
Jamb depth is the fourth number, and it must match the wall. A standard 2 by 4 wall with drywall on both sides takes a 4-9/16 inch jamb: 3.5 inches of stud plus 0.5 inch of drywall on each side, which is 3.5 + 0.5 + 0.5 = 4.5 inches, sold as 4-9/16 inches. A 2 by 6 wall takes a 6-9/16 inch jamb: 5.5 + 0.5 + 0.5 = 6.5 inches, sold as 6-9/16 inches. A jamb that is too shallow leaves a step at one wall face; a jamb that is too deep sticks past the other. Measure the full wall thickness, drywall face to drywall face, before ordering a prehung unit.
Code and accessibility: what the numbers must do
Two different rulebooks set doorway minimums, and they apply to different houses, so keep them separate.
The residential egress rule (IRC R311.2). Every dwelling unit needs at least one exit door. That door must be side-hinged, must provide a clear width of at least 32 inches measured between the face of the door and the stop with the door open at 90 degrees, and must provide a clear height of at least 78 inches measured from the top of the threshold to the bottom of the stop. Other doors in the house are not required to meet those minimums, which is why a 28 inch bathroom door is legal in a house whose front door must clear 32 inches. The egress door must also open readily from inside without a key, special knowledge, or special effort. Fine Homebuilding's code explainer draws the practical conclusion directly: these minimums explain why 36 by 80 inch entry doors became the standard, because that slab comfortably clears both the 32 inch width and the 78 inch height minimums.
The accessible route rule (ADA Standards 404.2.3). Doors on an accessible route must provide a clear width of at least 32 inches, measured the same way, between the face of the door and the stop with the door open at 90 degrees. Openings more than 24 inches deep must provide 36 inches clear instead, because a deep passage behaves like a short hallway and a wheelchair needs the extra width to enter it. Nothing may project into the required clear width below 34 inches above the floor, and projections between 34 and 80 inches high may stick out no more than 4 inches. The clear height minimum is 80 inches, with door closers and stops allowed down to 78 inches. Where a doorway has two leaves, at least one active leaf must provide the full 32 inch clear width on its own: a pair of 30 inch leaves gives a 60 inch total and still fails, because neither leaf alone clears 32 inches.
Which rule applies to your house? The IRC egress rule applies to homes generally, through the locally adopted residential code. The ADA Standards apply to public accommodations, commercial facilities, and state and local government facilities, not as a mandate for a private single-family home. A private homeowner is not legally required to make every interior door ADA compliant, but the 32 inch clear figure is still the right planning target for any doorway a wheelchair user, a walker user, or a wide delivery must use, because it is the figure every accessible standard agrees on. Check your local adopted code before building, because local amendments can be stricter than either rulebook, and this guide is a planning reference, not a permit approval.
Height: 80 inches standard, 78 inches the floor
Height causes fewer arguments than width, but it has the same three-number structure, so run it the same way.
| Door height | Slab height | Clear height, about | Rough opening height | Where it fits |
|---|---|---|---|---|
| Standard | 80 in (6 ft 8 in) | 78 to 80 in | 82.5 in | Most homes, 8 ft ceilings |
| Tall | 84 in (7 ft) | 82 to 84 in | 86.5 in | 9 ft ceilings, modern builds |
| Extra tall | 96 in (8 ft) | 94 to 96 in | 98.5 in | 10 ft ceilings, grand entries |
The clear height floor is 78 inches for the egress door (threshold to stop) and 80 inches for an accessible route (78 inches allowed at closers and stops). An 80 inch slab clears the egress floor with 2 inches to spare, which is the same margin logic as the 36 inch width. A threshold eats height from the bottom and a closer or stop eats it from the top, so measure clear height from the top of the finished threshold to the lowest point of the stop or closer, not from the subfloor to the header. Finished flooring changes this reading: a door measured before thick flooring goes down can lose a fraction of an inch of clearance after it, and a door that drags on new flooring is usually a height measurement taken too early, not a door defect.
Metric readers can convert with one multiplier: inches times 2.54 equals centimeters. A 32 inch clear opening is 81.3 cm, a 36 inch slab is 91.4 cm, an 80 inch door is 203.2 cm tall, and an 82.5 inch rough opening height is 209.6 cm. Those four conversions cover most ordering conversations with a metric supplier.
Width by room: which number fits which door
A front door carries the most jobs in the house: egress, deliveries, wheelchair access, and weather resistance. Size it at 36 by 80 inches, 1-3/4 inches thick. Side and back doors sometimes run narrower, at 32 or 30 inches, but any door that serves as the dwelling's egress door must still clear the 32 inch opening rule, so a 30 inch side door cannot be the only egress door. If a side door is the egress door, it needs the 36 inch slab, not the 30 inch one.
A bedroom door carries daily walking and the occasional furniture move. Size it at 30 to 32 inches, with 32 inches as the common pick, 1-3/8 inches thick. A 32 inch bedroom door gives about 30 inches clear, which is comfortable for walking and for carrying a laundry basket, and it fails only the accessibility test, which most bedroom doors are not asked to pass. If the bedroom is for a wheelchair user or for aging in place, size it at 36 inches like the front door, because retrofitting a wider bedroom door later means reframing, not just rehanging.
A bathroom door carries one person at a time into the smallest room in the house, and it is the door most often squeezed to save wall space. Size it at 28 to 30 inches, with 28 inches as the common pick. A 28 inch bathroom door gives about 26 inches clear, which is tight for a walker and impassable for a wheelchair, so an accessible bathroom needs the 36 inch slab regardless of what the rest of the house uses. A pocket door is a common bathroom choice, because it removes the swing from a small room, and its sizing is covered in the door types section.
A closet door is really an access opening, not a passage, and its width follows what must come out of the closet. Bifold openings run 24 to 36 inches wide, and the folded panels give less clear access than the full opening width, because the folded leaves still occupy part of it. For the closet itself, depth, width, and rod height matter more than the door number, and our guide to coat closet dimensions sizes those three for an entry closet, while this article sizes only the opening it opens through. Do not shrink a closet door to save a few inches of wall and then discover that a bulky coat or a storage bin cannot come out through it.
Utility, laundry, and pantry doors sit at the narrow end of the interior range, at 24 to 30 inches. A 24 inch door gives about 22 inches clear, which passes a person sideways and fails almost everything else, so reserve 24 inches for true utility closets where only a person passes, and use 28 to 30 inches anywhere an appliance, a bin, or a vacuum must travel. A washing machine's depth with hoses is the usual surprise here, and the appliance, not the person, should set the door width.
Door types: hinged, double, pocket, bifold, sliding
Single hinged doors are the default, and every number in this guide so far describes them. They are also the only type the egress rule names directly, because the rule requires a side-hinged door. Their cost is floor space: the swing arc, covered in the next section, must stay clear on one side.
Double doors come in total widths of 60, 64, or 72 inches, which are two leaves of 30, 32, or 36 inches each: 30 + 30 = 60, 32 + 32 = 64, 36 + 36 = 72. The total is the wrong number to check. Check the active leaf: where a 32 inch clear opening is required, at least one leaf must give it, so a 64 inch double door with two 32 inch leaves fails that test (each leaf gives about 30 inches clear) while a 72 inch double door with two 36 inch leaves passes it (each leaf gives about 34 inches clear). Double doors also need a combined rough opening: combined slab width plus 2 inches, so 72 inches of slabs want a 74 inch rough opening, and 60 inches want 62 inches.
Pocket doors slide into the wall instead of swinging, which saves the swing floor space and costs wall space instead. The rough opening for a pocket door runs about twice the door width, because the wall must hold both the opening and the pocket the door slides into: a 32 inch pocket door wants roughly a 64 inch rough opening, which is 32 + 32 = 64 inches. Pocket doors suit bathrooms and tight rooms where a swing would hit a fixture, but they cannot carry the egress job in the same way a side-hinged door does, and they need a wall with no plumbing, wiring, or switches in the pocket zone.
Bifold doors fold in panels and suit closets, because they open most of the opening without a swing. Their clear access is less than the opening width, because the folded panels stack at the sides, and their track and pivots need their own small allowances. Size a bifold opening by the access it leaves, not by the opening it covers, and check the folded stack against the widest thing the closet must release.
Sliding and barn doors hang on a track and slide beside the opening instead of into it. They need clear wall beside the opening about as wide as the slab itself, on the side the door slides to, plus track clearance above. A sliding door that covers a 36 inch opening needs about 36 inches of free wall beside it, and a barn door needs the same plus room for the hardware. They suit wide openings and rooms where a swing would hit furniture, and they suit accessibility less well than a hinged door, because the sliding panel and its track can leave a smaller clear opening than the frame suggests. Measure the clear opening with the panel fully open, not the frame width.
Swing space: the floor a door needs
A door is not just an opening. It is a moving panel, and its swing occupies floor on one side. The swing zone is a quarter circle with a radius equal to the door width, and its area follows one formula:
Swing area = 3.1416 x door width squared / 4 / 144 (square feet)
| Door width | Swing area | Check |
|---|---|---|
| 28 in | 4.28 sq ft | 3.1416 x 784 / 4 = 615.8 sq in; / 144 = 4.28 |
| 30 in | 4.91 sq ft | 3.1416 x 900 / 4 = 706.9 sq in; / 144 = 4.91 |
| 32 in | 5.59 sq ft | 3.1416 x 1024 / 4 = 804.2 sq in; / 144 = 5.59 |
| 36 in | 7.07 sq ft | 3.1416 x 1296 / 4 = 1017.9 sq in; / 144 = 7.07 |
A 36 inch door sweeps 1.48 square feet more floor than a 32 inch door (7.07 – 5.59 = 1.48), which is the price of the wider passage. Keep that zone clear of consoles, shoe storage, and rug edges that bunch under the swing. Where a door opens at the top or bottom of a stair, the swing must also clear the landing, and landing sizes belong with the stair, not with the door: our guide to staircase dimensions sizes the landing itself, while this article checks only that no door swing crosses it. A door that swings across a landing approach or into a hallway pinch point fails in use even when its own width passes on paper, and flipping the swing into the room is usually cheaper than widening anything.
Where two doors face each other or sit close together, tape both arcs on the floor before placing furniture. Opposing doors open into the same floor zone, and a console that looks fine against a closed door becomes a collision when the door opens onto it. Out-swinging doors (into a hall) are kinder to the room and harder on the hall; in-swinging doors (into the room) are kinder to the hall and harder on the room. Choose the swing by which side can afford the quarter circle, not by habit.
Moving furniture through a doorway: the boundary
This article owns the doorway numbers. The measuring workflow for getting furniture through them belongs to its own guide, and the two should not be merged, because a reader buying a door and a reader moving a sofa need different checklists. For the numbers side, two doorway figures matter to a move: the clear opening width and the opening diagonal. The diagonal of a 36 by 80 inch opening is the square root of (36 squared plus 80 squared), which is the square root of (1296 + 6400), which is the square root of 7696, which is 87.7 inches. The diagonal of a 32 by 80 inch opening is the square root of (1024 + 6400), which is the square root of 7424, which is 86.2 inches. A tall piece tilted through the opening rotates on that diagonal, which is why a piece taller than the opening height can still pass it on a tilt.
For the workflow itself, the route walk, the furniture numbers, the tightest-spot comparison, and what to remove when the numbers miss, read our guide to measure furniture for doorways. That guide keeps the delivery-route checklist, including the rule that the tightest spot on the whole route decides the delivery. This article supplies the doorway numbers that checklist tests against, and nothing more: clear opening, height, diagonal, and swing are the doorway inputs, and the rest of the route (hall width, stair turn, elevator) is measured in that guide.
Widening a doorway: what a 4 inch change really costs
The most common widening job is swapping a 32 inch interior door for a 36 inch one. The arithmetic is small and the work is larger than it looks. The rough opening grows from 34 inches to 38 inches, which is 38 – 34 = 4 inches of extra framed width. The slab grows by 4 inches, the clear opening grows from about 30 inches to about 34 inches, and the swing area grows by 1.48 square feet. Those are the gains.
The costs are structural and cosmetic. Four inches of framing must come out of the wall on one or both sides, which means moving a stud, and if the wall is load-bearing, the header above the opening must be checked and possibly resized before any stud moves. The trim, casing, and paint on both sides need redoing, the flooring may show a gap where the old frame sat, and a door that widens toward a light switch, an outlet, or a perpendicular wall may need those moved too. Widening toward the hinge side versus the latch side changes which trim and which wall section moves, so decide the direction before cutting. If the doorway sits in a wall with plumbing or wiring in the way, the job grows again. Get a builder's look before cutting a load-bearing wall, and check the local code, because a widened egress door still needs its 32 inch clear opening and 78 inch clear height after the work, measured the same way as before.
A cheaper widening exists for a marginal miss: removing the door from its hinges typically frees an inch or two of clear width, and removing the stop or the hinges from the jamb frees a little more. That is a moving-day trick, not a renovation, and it belongs in the furniture workflow guide, not in a framing plan. If the route card still fails after the door, the hinges, and the furniture's removable parts are off, the doorway needs reframing or another entrance, not more force.
How to measure a doorway
- Measure the slab width and height from the panel itself, edge to edge, not from the frame, and note the thickness: 1-3/8 inches for interior, 1-3/4 inches for exterior.
- Open the door to 90 degrees and measure the clear width from the face of the door to the opposite stop, at the narrowest point, and the clear height from the top of the threshold to the bottom of the stop.
- Measure the rough opening only if the trim is off or the wall is open: stud to stud for width, subfloor or finished floor (note which) to header for height, and drywall face to drywall face for jamb depth.
- Measure the swing arc on the floor: tape a quarter circle with a radius equal to the door width on the swing side, and check it against furniture, consoles, and landing approaches.
- Measure the opening diagonal from the top corner of the clear opening to the opposite bottom corner, because that is the number a tall piece rotates on.
- Measure every doorway on the route separately, and plan from the smallest clear opening, because the narrowest doorway decides the route.
- Walk the doorway carrying something bulky, such as a laundry basket, and note every spot where you turn sideways, because that spot is the real pinch, whatever the tape says.
Common mistakes to avoid
Quoting the slab as the passage. A 32 inch door is not a 32 inch passage. It is about a 30 inch passage, and it fails the 32 inch minimum. Quote the clear opening whenever the question is whether something passes.
Measuring the frame instead of the clear opening. The frame, the jamb, and the trim are all wider than the passage. Measure face of door to stop at 90 degrees, or the number is fiction.
Forgetting the threshold and the closer. Clear height is measured from the top of the threshold to the bottom of the stop, and a closer or a high threshold can eat the margin an 80 inch door seemed to give.
Ignoring the swing. A doorway that passes on width and fails on swing blocks a hall, a landing, or a console every time it opens. Tape the arc before placing furniture beside a door.
Checking the total on a double door. A 60 inch double door is two 30 inch leaves, and neither leaf alone gives 32 inches clear. Check the active leaf, not the total.
Assuming every interior door is the same size. Bedroom, bathroom, closet, and utility doors commonly differ by 2 to 8 inches in the same house. Measure each one, and never order a replacement from a neighboring door's size.
Widening a hall to fix a single doorway. A narrow doorway is a doorway problem, not a hallway problem, and widening the hall wastes floor along the whole run. Fix the doorway, or move the furniture route, before touching the hall.
Frequently asked questions
How wide is a doorway?
A standard doorway is 36 inches wide at the front door and 30 to 32 inches wide inside, measured as the slab. The passage that matters is the clear opening: about 34 inches for a 36 inch door, and about 30 inches for a 32 inch door. The code and accessibility minimum for the clear opening is 32 inches.
How tall is a doorway?
A standard doorway is 80 inches tall, which is 6 feet 8 inches, for interior and exterior doors alike. Taller options are 84 inches for 9 foot ceilings and 96 inches for 10 foot ceilings. The clear height minimum is 78 inches for an egress door, measured from the top of the threshold to the bottom of the stop.
What is the minimum doorway width?
The minimum clear opening is 32 inches wide and 78 inches high for a dwelling's egress door under the residential code, and 32 inches wide and 80 inches high for a door on an accessible route under the ADA Standards. A 36 inch slab is the smallest common door that clears the 32 inch width minimum with margin, giving about 34 inches clear.
What size doorway do I need for a wheelchair?
Use a 36 inch slab, which gives about 34 inches of clear opening, comfortably above the 32 inch accessible minimum. Make sure the clear width is measured with the door open at 90 degrees, face of door to stop, and keep projections below 34 inches high out of the opening entirely. For an opening deeper than 24 inches, the accessible minimum rises to 36 inches clear.
What size is a bedroom door?
A standard bedroom door is 30 to 32 inches wide by 80 inches tall, with 32 inches as the most common pick. For a wheelchair user or for aging in place, use 36 inches instead, because a 32 inch bedroom door gives only about 30 inches clear.
What size is a front door?
A standard front door is 36 inches wide by 80 inches tall and 1-3/4 inches thick. Double front doors total 60, 64, or 72 inches wide, made from two leaves of 30, 32, or 36 inches, and at least one leaf must give 32 inches clear where a clear opening is required.
What is the rough opening for a 32 inch door?
The rough opening for a 32 by 80 inch door is 34 by 82.5 inches: slab width plus 2 inches, slab height plus 2.5 inches. For a prehung unit, confirm the manufacturer's own rough opening spec, especially for an exterior door, where thicker jambs and the sill can shift the number slightly.
Can a doorway be 28 inches wide?
Yes, for an interior door that is not the egress door and not on an accessible route. A 28 inch slab gives about 26 inches clear, which passes a person and fails a wheelchair, a walker, and most furniture moves. Keep 28 inches for small bathrooms and utility spaces, and use 36 inches anywhere access or deliveries matter.
Sources
- Doors.com, Standard Door Size: A Complete Guide for Residential Homes: https://www.doors.com/pages/standard-door-size
- Statement Design Concepts, What Is the Standard Door Size for Residential Homes?: https://statementdesignconcepts.com/what-is-the-standard-door-size-for-residential-homes/
- Window Sunshine, Standard Door Size Guide: Interior, Exterior and Front Door Dimensions: https://www.windowsunshine.com/Standard-Door-Size-Guide-Interior-Exterior-Front-Door-Dimensions-id02966525.html
- ADA Standards for Accessible Design, Section 404, Doors, Doorways, and Gates (Corada reproduction): http://www.corada.com/documents/2010ADAStandards/404?highlight=404
- Fine Homebuilding, A Code Pro Explains What the 2024 IRC Says About Exterior Doors: https://www.finehomebuilding.com/project-guides/windows-doors/exterior-doors-decoded
- Engineer Fix, What Is the Rough Opening for a Prehung Door?: https://engineerfix.com/what-is-the-rough-opening-for-a-prehung-door/
- Sensible Digs, How to Measure a Door: Slab, Pre-Hung and Sliding: https://sensibledigs.com/how-to-measure-a-door/
- Opple House, Door Rough Opening Dimensions: What You Need to Know: https://opplehouse.com/door-rough-opening-dimensions-what-you-need-to-know/
- Live sibling pages (internal, verified 2026-11-02): staircase-dimensions (7-11 rule, 36 in minimum stair width, landing sizes), measure-furniture-for-doorways (delivery-route checklist, clear opening method, tightest-spot rule), coat-closet-dimensions (24 in depth, 36 in width, rod 66 to 70 in, bifold access narrower than the opening)


5 Comments
Pingback: Hallway Dimensions: The 36-48-60 Width Chart for Every Hall
Pingback: Washing Machine Dimensions: The Size Chart + Delivery-Path Check
Pingback: Shower Dimensions: Size Chart + the 60 Inch Doorless Rule
Pingback: Bathtub Dimensions: Size Chart + the 60 by 30 Rule
Pingback: Coat Closet Dimensions: 24 in Deep, 36 in Wide (Chart)